Note: for the errors listed below, you may click “Clear” to check related parts.
Error Number
Error
Solutions
EC08
Pll bar
Press “” button ➜
Back to the beginning, thenpull backward bar again
The operating error.
No such design in memory
Select other designs.
Main shaft not stop inposition1. Turn the handwheel by hand, until to on screen.2. Press button.
Frame over border.
1. select the frame consistent with actual size
2. select “no”. turn off this function.
Replace battery on mainboard
Sep motor
1.check Mechanical transmission2.check X Y motor3.check X Y driver
Color changing overtime
1.check the color motor. Check motor driver board PC501/PC502.
2.check the sensor.
Color changing half rotationabnormalAdjust by turning the handwheel by hand.
Need position abnormal1.Adjust by turning the handwheelby hand.
2. check thesensor.
Main motor overtime.
1.turning the handwheel by hand Check whether the load is too heavy;2.turning the handwheel by hand At least one circle ,there is a change , observe the icon on screen. ifno change,clear or replace E923 board.
3.Test “machine Test” ➜ “Test Encoder Parameters”
Main motor overtime.
1.turning the handwheel by hand Check whether the load is too heavy;2.turning the handwheel by hand At least one circle ,there is a change , observe the icon on screen. ifno change,clear or replace E923 board.
10APL 2000 ± 3BPL 2000 ± 3If not right,check motror encoder plug connect to driver.4. Replace driver.
Color changing out.
“Needles” parameter setting mustequal to the machine’ s actual needles. 9 or 12 or 15.
Trimming not in position. Check whether the detection sensor is damaged.
Files not exist in disk.
1.Try again.2.Restart machine and then try again.3.execute “clear All Designs”. Input designs again.
Disk dir full.
Delete useless Designs. Free Memory.
Disk space full.
Delete useless Designs. Free Memory.
File distribution list error.execute “clear All Designs”.
Dir error. execute “clear All Designs”.
The same method as EC20.